SIGN BOARD


Digi-Dot Sign Control - DSC (windows based control software)

Remote Programming

Check the Sign ID you wish to communicate with and then click Remote. When the on-board GSM cell modem connects it displays the battery voltage; click OK; and then the window below appears named 1TDO-625 (whatever is in the Sign ID data).
All commands are identical; when you click Close, the modem hangs up.

DSC Dialling DSC Connecting DSC BatteryVoltage
Click Remote and Dialling appears followed by Connecting and Sign ID check; and then Battery Voltage. Click OK; and DSC Sign ID window is ready.

DSC Remote Connected

The window shows the current Frame switch number (6), click Monitor and the real time message will be displayed. Click Monitor again to return; you may type your new message and press program! Click Close and the modem hangs up.
That's how simple it is to remotely control your DIGI-DOT Sign.

Local Connection

Serial cable connecting notebook with sign (pins 2, 3, 5 pin to pin) allows Local control. Click on Local and then Tasks as shown below; click on Tasks to return to the Local window.

Click Local; write message; click Tasks to Save Message

Local Programming

Click on Local and the local connection screen is displayed.

Click Local and write your message (1-10 pages)

Slide boxes to the required Frame number (Rotary Switch positions 0 - 36) and your message is comprised of between 1 and 10 Pages. Mark lines to blink, display left or right arrows, and edit the time in seconds. This Local Connection window can be saved by clicking Tasks then Save Preferences and will display these defaults on initial window.
Click the message line and type your word (up to 8 characters), always use the up/down arrow keys for next line. For the next page, just click on the Page slider. When your message is complete, you may edit it by using the Page slider. Click on Program and message has been loaded in sign.
Click on Monitor and the notebook will show what the sign is displaying. Click Close to exit.

Initial Set-up

Windows based software making downloading messages fast, reliable, and simple. Double click DSC, enter your password and data base appears. Click on Tools, Edit Sign Data and complete details. Depot has a filter, and if checked, only signs at that Depot appear in the sign data base (as shown). Set up Com Options and User Password and you are ready for sign control. You only need to do it once; unless making changes or adding new signs.

Click Tools
and complete initial set-up

Time Schedule

Complete an excel spreadsheet by double clicking Schedule .xls; complete the time(s) and date(s) for messages to display. Click Messages tab and write your text. Once the spreadsheet is saved, DSC enters all information automatically! 48 separate times and up to 24 separate messages can be entered and controlled from your notebook or PC.

ADDCO welcome your comments... email us.